4.27 KEW6305
Setting 25” Setting save
Following explains how to save the settings items.
Seven items below can be saved.
Making necessary settings on following 7 items, and saving them. Then it can be loaded from Setting
24 from the next time. Selectable number: 01 - 20
Setting no.
Setting 01 Wiring system
Setting 02 Voltage range
Setting 03 Clamp sensor
Setting 04 Current range
Setting 05 VT ratio
Setting 06 CT ratio
Setting 08 Buzzer
1 Above 7 items are set when needed. (Please refer to each setting procedure.)
2 Select Setting 25 with the Cursor key on the selection screen.
3 Press the ENTER key to get the instrument into setting change mode.
4 Select the Setting save number (01 - 20) with the Cursor key.
5 Press ENTER key after making necessary settings.
NOTE:
* When new settings are made on the setting save number, on which settings already have done, the
previous setting will be overwritten.
* All the saved items (settings) will restore to default after system-reset.
150V 300V 600V 1P2W 1P3W 3P3W 3P4W
5A 10A 20A 50A 100A 200A 500A 1000A
Setting save number