Supplementary sheet KEW6310Quick manual (English)
Supports 2G / 4G / 8GB CF cards.
Operation check has completed
Supplier 2GB 4GB 8GB
SanDisk Corp.
Ultra II 15MB/s CF 2GB
SDCFH-002G
Ultra II 15MB/s CF 4GB
SDCFH-004G
Ultra II 15MB/s CF 8GB
SDCFH-008G
*
This instrument supports FAT16 and cannot save data of 2GB or more if a
card of 4GB or more is used.
(Identified as over capacity when the area of usage exceeds 2GB.)
Max possible recoding time
Twice the recording time for 1GB
e.g. Demand measurement with an interval of 1 sec
1GB: 5 days, 2GB or more: 10 days
*
Max number of file is 512 regardless of memory capacity.
Seitenansicht 0
1 2 3 4 5 6 ... 44 45

Inhaltsverzeichnis

Seite 1 - SanDisk Corp

Supplementary sheet (KEW6310Quick manual) (English) Supports 2G / 4G / 8GB CF cards. ● Operation check has completed Supplier 2GB 4GB 8GB SanDisk

Seite 2 - KEW 6310

Charging the rechargeable Ni-MH batteries   Following message to prompt battery charge appears on the LCD automatically when battery level is 40% or

Seite 3

KEW6310Cord Connection KEW6310− 9 −Cord ConnectionStart-up Screen  Model name and software version will be displayed upon powering on the instrum

Seite 4 - 1.Instrument Overview

KEW6310KEW6310  Setting− 10 −4.Setting The “SET UP” consists of following 4 settings.Basic Setting : Setting of the items common to all measurements

Seite 5 - Functional Overview

KEW6310Basic Setting  KEW6310− 11 −Basic SettingSetting item Details of SettingWiring①1P2W×1 ②1P2W×2 ③1P2W×3④1P2W×4 ⑤1P3W×1 ⑥1P3W×2⑦1P3W×1+2A ⑧3P3W

Seite 6 - Power quality analysis

Reverse clamping switches the symbols (+/-) for active power.KEW6310KEW6310  Basic Setting− 12 −Orientation of Clamp sensorPowerSupplyLoadArrow mark:

Seite 7 - 2.Instrument Layout

KEW6310Measurement Setting  KEW6310− 13 −Measurement SettingSetting Item Details of SettingW╱Wh╱DEMAND*W Instantaneous/avg/max/min valuesON╱OFFWh D

Seite 8 - Battery Case

Measurement SettingSetting Item Details of SettingInterval1sec╱2sec╱5sec╱10sec╱15sec╱20sec╱30sec╱1min╱2min╱5min╱10min╱15min╱20min╱ 30min ╱1hour* Inte

Seite 9 - 3. Getting Started

− 15 −5.Instantaneous (Inst) value measurement Steps for measurement    Ensuring your safety        ↓  Preparation for measurement        ↓       Se

Seite 10 - How to install batteries:

Header of the saved data A V G _ A 1 [ A ] _ 1 ︸     ︸ ︸  ︸     ︸   ①    ② ③  ④    ⑤             * Saved data with no number at this space contai

Seite 11 - Start-up Screen

− 17 −6.Integration value measurement Steps for measurement    Ensuring your safety        ↓  Preparation for measurement        ↓       Setting

Seite 12 - 4.Setting

Quick manualPOWER QUALITY ANALYZERKEW 6310

Seite 13 - Basic Setting

.Header of the saved data INTEG_WP+[Wh]_1  ︸     ︸    ︸     ︸    ①      ②    ③    ④Saving integration values1Press Start → Next → Next → C

Seite 14 - Orientation of Clamp sensor

− 19 −Demand measurement   KEW63107.Demand measurement Steps for measurement   Ensuring your safety        ↓  Preparation for measurement        ↓ 

Seite 15 - Measurement Setting

KEW6310  Demand measurement Header of the saved data INTVL_WP+[Wh]_1 ︸    ︸    ︸     ︸    ①      ②    ③    ④                     * ②,③,④ will b

Seite 16 - Save Setting

− 21 −Demand measurement  KEW6310 KEW6310Measurement ScreenShifts in specific periodDigital output signal warns when the predicted value exceeds the

Seite 17 - Save data

KEW6310  Demand measurementKEW6310− 22 −Demand changeDemand startTarget valueDemand valueDemand terminationMax demand value( d i s p l a y e d o n

Seite 18 - Saving instantaneous values

− 23 −WAVE Range  KEW63108.WAVE Range Steps for measurement    Ensuring your safety        ↓   Preparation for measure

Seite 19

KEW6310  WAVE RangeHeader of the saved data File ID : 6310-04 (Waveform data)    5/133     ︸  ︸     ①   ② File ID : 6310-05 (Vector data) INST_A1

Seite 20 - Saving integration values

− 25 −9.Harmonic Analysis Steps for measurement    Ensuring your safety        ↓  Preparation for measurement        ↓      Setting        ↓       Wi

Seite 21 - 7.Demand measurement

Save dataFile ID : 6310-06Saved time & date ELAPSED TIME Channel RMS Total THD Inst at each orderDATE TIME ELAPSED TIME CH TOTAL THD1_[V/A]∼63_[V/

Seite 22 - Saving of demand values

10.Power Quality Swell / Dip / Int measurementSteps for measurement    Ensuring your safety        ↓  Preparation for measurement        ↓       S

Seite 23 - Shifts in specific period

− 1 − KEW6310Contents KEW6310●Preface  This Quick manual is a simplified version of the full instruction manual which can be found in the supplied CD-

Seite 24 - Demand change

Duration Max / Min DataDURATIONMAX/MIN 201--:--:--.-- h:mm:ss.ss (±)x.xxxE±nnstartend max(Swell) min(Dip/Int) (±) value x 10±10File ID : 6310-13Saved

Seite 25 - 8.WAVE Range

− 29 −Transient measurement  KEW6310Transient measurementSteps for measurement    Ensuring your safety        ↓  Preparation for measurement      

Seite 26 - Saving at WAVE Range

KEW6310  Transient measurementSave dataFile ID : 6310-08Saved time & date Max DataDATETIME MAX 201 datayyyy/mm/dd h:mm:ss.ss (±)x.xxxE±nnyear/mon

Seite 27 - 9.Harmonic Analysis

− 31 −Inrush Current Measurement  KEW6310Inrush Current MeasurementSteps for measurement    Ensuring your safety        ↓  Preparation for measurem

Seite 28

KEW6310  Inrush Current MeasurementSave dataFile ID : 6310-09Saved time & date Start / End Duration Max / Min DataDATE TIME I╱O DURATION MAX/MIN

Seite 29 - Swell / Dip / Int measurement

− 33 −Unbalance Ratio  KEW6310Unbalance RatioSteps for measurement   Ensuring your safety        ↓  Preparation for measurement        ↓      Setti

Seite 30

KEW6310  Unbalance RatioHeader of the saved data  AVG_A1[A]_1   ︸    ︸ ︸  ︸  ︸    ①   ② ③ ④   ⑤        *Saved data with no number at this space

Seite 31 - Transient measurement

− 35 − KEW6310Flicker* An optional voltage sensor KEW8325F is required for Flicker measurement.Steps for measurement   Ensuring your safety        ↓ 

Seite 32

− 36 −KEW6310KEW6310  FlickerVPst(1min)Plt

Seite 33 - Inrush Current Measurement

Capacitance Calculation - Sizing of capacitor banks for Power factor correction (PFC)Steps for measurement     Ensuring your safety        ↓  Prepara

Seite 34

KEW6310KEW6310 Instrument Overview− 2 −1.Instrument OverviewFeature  This is a Clamp-type Power Quality Analyzer that can be used for various wir

Seite 35 - Unbalance Ratio

KEW6310  Capacitance CalculationHeader of the saved data  AVG_A1[A]_1   ︸    ︸ ︸  ︸  ︸    ①   ② ③ ④   ⑤          * Saved data with no number

Seite 36 - AVG_A1[A]_1

CF Card / Saved data KEW6310− 39 −11.CF Card / Saved dataCF Card (operation check has completed)Capacity 32MB 64MB128MB256MB 512MB 1GBSanDisk Corp.*

Seite 37 - Saving Flicker data

KEW6310 Data transferData transfer  Data in the CF card or internal memory can be transferred to a PC via USB connection or CF card reader.Transfer

Seite 38 - KEW6310  Flicker

Configuration file File Name : ME 000123 .KAS          ①   ②    ③ Bitmap file File Name : PS − CF 001 .BMP     ①    ②  ③  ④Backup Memory In case on

Seite 39 - Capacitance Calculation

12. Wiring check Proper wirings can be checked at WAVE Range.1. Ordinal screen 2. Checking wiring 3. Check completesPress the F2 Key.Wiring check

Seite 40

10-08 92-1882BDISTRIBUTOR

Seite 41 - 11.CF Card / Saved data

KEW6310Functional Overview KEW6310− 3 −Functional OverviewInstantaneous value measurementMeasures average/max/min values of instantaneous values

Seite 42 - File format and name

KEW6310KEW6310 Functional Overview− 4 −Measurement at WAVE RangeDisplays vector / waveform of voltages and currents per CHSee (Section 8) WAVE Range

Seite 43 - Backup Memory

KEW6310Instrument Layout KEW6310− 5 −2.Instrument LayoutFront viewMenu KeyWMeasuresinst valuesWaveform Measures waveformsWhMeasures integration val

Seite 44 - 12. Wiring check

Voltage Input Terminal(VN, V1, V2, V3)Current Input Terminal(A1, A2, A3, A4)Terminal CoverPower ConnectorBattery CoverSelector switch coverSelector sw

Seite 45 - DISTRIBUTOR

KEW6310Getting Started KEW6310− 7 −3. Getting Started  The KEW6310 operates with either an AC power supply or batteries. In the event of AC