Inhaltsverzeichnis

Seite 1 - INSTRUCTION MANUAL

MODEL1009オートレンジ デジタル マルチメータ・AUTO RANGE DIGITAL MULTIMETERKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.,取扱説明書INSTRUCTION MANUAL

Seite 2 - 1. Safety Warnings

―20―6-4 Capacitance MeasurementDANGER● To avoid the danger of getting electrical shock, never make measurement of the circuit in which electric poten

Seite 3

―21―● Current function (uA, mA, A)When setting the instrument to any function of the "uA", "mA", and "A", DC Current Mea

Seite 4 - 3. Specification

―22―8. Auto Power OffAuto power off function operates when about 30minutes passed after power on this instrument.When Auto power off function operates

Seite 5 - Diode check

保 証 書共立製品をお買い上げいただきありがとうございます。保証期間内に通常のお取扱いで万一故障が生じた場合は、左記の保証規定により無償で修理いたします。本書を添付の上ご依頼ください。お名前ご住所 〒お電話番号  ( )−( )−( )◎保証規定をよくお読みください。◎本保証書は日本国内でのみ有効で

Seite 6 - 4. Instrument Layout

―12―1. Safety WarningsThis instrument has been designed, manufactured and tested according to the following standards.IEC 61010-1 Over voltage CATⅢ 30

Seite 7 - 6. Measurements

―13―CAUTION● Always make sure to check Function switch is setting to the appropriate range before starting measurement.● Do not expose the instrument

Seite 8

―14―2. FeaturesThis instrument, 1009, is a Digital Multimeter which designed for making measurement of the low-voltage equipment.(1) Designed to inter

Seite 9

―15―● Standards IEC61010-1 Overvoltage CATⅢ 300V, pollution degree 2 / Overvoltage CATⅡ 600V, pollution degree 2IEC61010-031IEC61326● Mode of operatio

Seite 10

―16―● Operating Environmental −indoor useconditions −altitude up to 2000m● Temperature & Humidity range(guaranteed accuracy) 23℃±5℃ Relative humid

Seite 11

―17―5. Preparation5-1 Checking Battery VoltageSet the Function Selector Switch to other positions except the OFF position.Battery Voltage is enough if

Seite 12 - 10. Maintenance

―18―(2) Set the Function Selector Switch to the appropriate "uA" or "mA" position.In case that the measurement current is 3999uA

Seite 13 - 保証期間  ご購入日 ( 年   月   日)より1カ年間

―19―(4) Power off the circuit under test.(5) Connect the test leads to the circuit under test so the instrument is in the series.(6) Power on the circ